Vaillant cv-ketel
Fault F.28: ignition failed
The boiler tries to ignite but sees no flame. Often the gas tap is closed, the gas supply is disrupted or the igniter is dirty or broken.
Do this first
- Check whether the gas tap by the boiler is open (the lever in line with the pipe).
- Do your gas hob or other gas appliances work? If not, the gas supply is the problem.
- Press reset once.
When should you call an engineer?
Komt F.28 na een reset terug, bel dan een monteur: de ontsteking, de ionisatiepen of de gasklep moet worden nagekeken. Ruik je gas? Raak geen schakelaars aan, zet ramen en deuren open, ga naar buiten en bel 0800-9009 (het landelijke storingsnummer voor gas en stroom).
Reset
Press the reset button once (on most ecoTEC models the button with the arrows or 'reset'). If the boiler goes into fault again, don't keep resetting but call an engineer.
Still under warranty?
Add your cv-ketel to your home file, with the installation date. Then you'll see whether it's still under warranty and get a reminder for servicing.
Add applianceWant to know more? Read central heating boiler not working: what now?
Frequently asked questions
What does F.28 mean on a Vaillant cv-ketel?
The boiler tries to ignite but sees no flame. Often the gas tap is closed, the gas supply is disrupted or the igniter is dirty or broken.
Can I fix F.28 myself?
Check whether the gas tap by the boiler is open (the lever in line with the pipe). Do your gas hob or other gas appliances work? If not, the gas supply is the problem. Press reset once. Komt F.28 na een reset terug, bel dan een monteur: de ontsteking, de ionisatiepen of de gasklep moet worden nagekeken. Ruik je gas? Raak geen schakelaars aan, zet ramen en deuren open, ga naar buiten en bel 0800-9009 (het landelijke storingsnummer voor gas en stroom).
Other Vaillant codes
- F.22 too little water in the boiler
- F.29 flame goes out while burning
- F.75 no pressure difference when the pump starts
- F.20 overheating
- F.00 flow sensor interrupted
- F.01 return sensor interrupted
- F.10 flow sensor short circuit
- F.27 flame detected while the gas valve is closed
- F.61 fault in the gas valve control
- F.62 gas valve closes too slowly
- F.63 memory error (eeprom)
- F.64 fault in electronics or sensor
- F.73 pressure sensor signal too low
- F.83 dry firing at burner start